 OPRIMA LABORATORY / PT OCTA PRIMA LESTARI Indonesia |
|
| | |
|
| TOTAL SUSPENDED PARTICULATE ( TSP ) STAPLEX |
 (Product Photo) |
| | TOTAL SUSPENDED PARTICULATE ( TSP ) STAPLEX
Model TSP-2 Total Suspended Particulate Air Sampling System, 220-230 VAC
These complete air sampling systems, available with various modular accessories, are designed to meet the EPA requirements for sampling airborne particulates at a known flow rate for a determined amount of time, allowing for proper calculation of airborne particulate concentrations.
Accessory Items
Timers
DTM-1 and DTM-2 Digital 7-Day Timer Turns Air Sampler " ON" and " OFF" at set times, 24 hours a day, 7 days a week. All functions are digital and quartz crystal controlled; includes digital clock with 1/ 4-in. LED display and 7.2 VDC rechargeable stand-by battery; intuitive programming format.
MT-1 and MT-2 Mechanical 7 Day Timer Turns Air Sampler " ON" and " OFF" at set times ± 15 minutes, 24 hours a day, 7 days a week. ; Model MLT-2 for 230 VAC, 50 Hz
DTM-4CDT Digital Countdown Timer Turns Air Sampler " OFF" after preset times. Features LCD display and thumb-wheel setting dials. ( range from 99, 999 hours to 1 second) . Size: 3" x 4-1/ 4" x 5" ( 7.6 cm x 10.8 cm x 12.7 cm) ; Weight: 1.75 lbs. ( 0.8 kg) .
ETI-2 Elapsed Time Indicator Shows sampler run time in hours and hundreths ( 99, 999.99 hours) . Standard models are non-resettable mechanical models.
Constant Flow Controllers FC-2
Automatically maintains a constant mass flow through an High Volume Air Sampler regardless of filter loading, atmospheric conditions and line voltage. [ requires SH810 filter holder assembly]
Models FC-1ETM and FC-2ETM include built-in non-resettable Elapsed Time Indicator.
Models FC-1MLT and FC-2MLT include built-in Mechanical 7-Day Timer and non-resettable Elapsed Time Indicator
Flow Recorder - ModeL FR-2 - Provides a permanent record of High Volume Air Sampler performance during a 24-hour period.
Calibration Kit - Models CKHV810 - U.S. EPA prescribed method for accurate calibration of High Volume Air Samplers. U.S. EPA recommends that High Volume Air Samplers be re-calibrated at least once per year ( or when major components such as the motor or flowmeter are changed) . Model CKHV810 can be used with 4" or 8" x 10" filter holder assemblies.
PM10 Size Selective Inlets - for U.S. EPA PM10 environmental air sampling. Staplex® PM10 Size Selective Inlet is available separately as Part No. PM10-SSI for conversion of existing TSP ( Total Suspend Particulate) High Volume Air Sampling Systems to PM10 System.
Staplex® No. PM10-SSI
PM10 Size Selective Sampling Inlet
* for use with Staplex® High Volume Air Sampling Systems
*
* separates thoracic particles smaller that 10 micron aerodynamic diameter
* meets U.S. EPA Reference Method specifications
Made in U.S.A.
The Staplex® PM10-SSI Size Selective inlet, used with Staplex® High Volume Air Sampler, 8" x 10' Filter Holder Assembly and Aluminum Outdoor Shelter and other available accessories, samples suspended particulates in the air at 40 ACFM ( 1.13 ACMM) through a circumferential inlet.
The symmetrical design insures wind-direction insensitivity. The Inlet design and internal configuration makes the collection efficiency independent of wind speed form 0 to 36 kilometers per hour. The air is accelerated though nine circular internal acceleration nozzles. By virtue of their larger momentum, particles greater than 10 micron aerodynamic diameter impact onto a greased impaction shim.
The PM10 particles of interest, that is those particles smaller than or equal to 10 microns, are carried vertically upward by the air flow and sown sixteen vent tubes to the 8” x 10” Quartz Fiber Filter ( Staplex® Type TFAQ810) , where they are collected for gravimetric airborne concentration analysis. The weight increase of the filter paper is considered the mass of PM10 particles collected. The mass concentration of PM10 particles is determined by dividing the particulate mass by the volume of air sampled.
Particles larger than 10 microns settle out of the impaction chamber on a collection shim and are removed when the collection shim is cleaned during prescribed maintenance periods.
PM10-SSI Specifications:
Net weight: 50-lbs. ( 22.7 kg)
Size: 28” ( 72 cm) diameter x 19” ( 48.3 cm) high
Click here for complete PM10 Air Sampling Systems
Staplex® No. PM-2.5SSI
PM2.5 Size Selective Sampling Inlet
Same sampling principle as PM10 except particles smaller than PM2.5 aerodynamic diameter collect on the quartz sampling filter
Also available as PM2.5-SSIRFK Retro Fit Kit for PM10 Air Sampling systems | | |
|
| Origin: | United States |
| Payment Method: | Cashier Order |
Your inquiry will be recorded in "Member Trade Mail". |
Recommend to your friends |
|
| Company Contact |
| Name: |
Mrs. HELEN / BPK . SANDI [Sales] |
| E-mail: |
Send Message |
| Mobile Number: |
081510069705 |
| Phone Number: |
62 21 - 85918154 - 85918155 - 85902391 & 70928154 |
| Fax Number: |
62 21 - 85918178 |
| Address: |
JL. MATRAMAN RAYA NO 148 , BLOK B-12 JAKARTA 13150, Jakarta Indonesia |
|